SR EN
Account Inquiry
Swivel lifting point G100 RLPSwivel lifting point G100 RLP

Group 02 · 65 items

Grade 80 and Grade 100 fittings

View the group →
Polyester ratchet lashing strap EN 12195-2 ERGO RATCHET RX-liftPolyester ratchet lashing strap EN 12195-2 ERGO RATCHET RX-lift

Group 04 · 16 items

Polyester slings

View the group →
Electric winch type DWElectric winch type DW

Group 06 · 38 items

Electric hoists, winches and pallet trucks

View the group →

Home/Products/Steel wire ropes and chains/General-purpose steel wire ropes/Steel wire rope 6x36WS with fibre core (FC)

Steel wire rope 6x36WS with fibre core (FC)

EN 12385-4 · DIN 3064 · Finish: self-coloured, electro-galvanised or hot-dip galvanised · Wire tensile strength: 1770 N/mm² or 1960 N/mm²

Choose the variant in the table — every row has “Add to inquiry”.

Overview

At a glance

Tags
  • Steel wire ropes
Table

Sizes and WLL

24 variants from the manufacturer’s table. Add a row to your inquiry — our sales team sends price and availability.

Steel wire rope 6x36WS with fibre core (FC) — variant table
Diameter (mm)Minimum breaking force (kN) 1770 N/mm2Minimum breaking force (kN) 1960 N/mm2Weight (kg/100 m)Add to inquiry
837.4041.423.50
947.3052.4029.7
1058.464.736.7
1170.7078.3044.4
1284.193.1052.8
1398.7109.062.0
14114.0127.071.9
16150.0166.094.0
18189.0210.0119.0
20234.0259.0147.0
22283.0313.0178.0
24336.0373.0211.0
26395.0437.0248.0
28458.0507.0288.0
30526.0582.0330.0
32598.0662.0376.0
36757.0838.0476.0
38843.0934.0530.0
40935.01040.0587.0
441130.01250.0711.0
481350.01490.0846.0
521580.01750.0992.0
561830.02030.01150.0
602100.02330.01320.0
  • Diameter (mm) 8
    Minimum breaking force (kN) 1770 N/mm2
    37.40
    Minimum breaking force (kN) 1960 N/mm2
    41.4
    Weight (kg/100 m)
    23.50
  • Diameter (mm) 9
    Minimum breaking force (kN) 1770 N/mm2
    47.30
    Minimum breaking force (kN) 1960 N/mm2
    52.40
    Weight (kg/100 m)
    29.7
  • Diameter (mm) 10
    Minimum breaking force (kN) 1770 N/mm2
    58.4
    Minimum breaking force (kN) 1960 N/mm2
    64.7
    Weight (kg/100 m)
    36.7
  • Diameter (mm) 11
    Minimum breaking force (kN) 1770 N/mm2
    70.70
    Minimum breaking force (kN) 1960 N/mm2
    78.30
    Weight (kg/100 m)
    44.4
  • Diameter (mm) 12
    Minimum breaking force (kN) 1770 N/mm2
    84.1
    Minimum breaking force (kN) 1960 N/mm2
    93.10
    Weight (kg/100 m)
    52.8
  • Diameter (mm) 13
    Minimum breaking force (kN) 1770 N/mm2
    98.7
    Minimum breaking force (kN) 1960 N/mm2
    109.0
    Weight (kg/100 m)
    62.0
  • Diameter (mm) 14
    Minimum breaking force (kN) 1770 N/mm2
    114.0
    Minimum breaking force (kN) 1960 N/mm2
    127.0
    Weight (kg/100 m)
    71.9
  • Diameter (mm) 16
    Minimum breaking force (kN) 1770 N/mm2
    150.0
    Minimum breaking force (kN) 1960 N/mm2
    166.0
    Weight (kg/100 m)
    94.0
  • Diameter (mm) 18
    Minimum breaking force (kN) 1770 N/mm2
    189.0
    Minimum breaking force (kN) 1960 N/mm2
    210.0
    Weight (kg/100 m)
    119.0
  • Diameter (mm) 20
    Minimum breaking force (kN) 1770 N/mm2
    234.0
    Minimum breaking force (kN) 1960 N/mm2
    259.0
    Weight (kg/100 m)
    147.0
  • Diameter (mm) 22
    Minimum breaking force (kN) 1770 N/mm2
    283.0
    Minimum breaking force (kN) 1960 N/mm2
    313.0
    Weight (kg/100 m)
    178.0
  • Diameter (mm) 24
    Minimum breaking force (kN) 1770 N/mm2
    336.0
    Minimum breaking force (kN) 1960 N/mm2
    373.0
    Weight (kg/100 m)
    211.0
  • Diameter (mm) 26
    Minimum breaking force (kN) 1770 N/mm2
    395.0
    Minimum breaking force (kN) 1960 N/mm2
    437.0
    Weight (kg/100 m)
    248.0
  • Diameter (mm) 28
    Minimum breaking force (kN) 1770 N/mm2
    458.0
    Minimum breaking force (kN) 1960 N/mm2
    507.0
    Weight (kg/100 m)
    288.0
  • Diameter (mm) 30
    Minimum breaking force (kN) 1770 N/mm2
    526.0
    Minimum breaking force (kN) 1960 N/mm2
    582.0
    Weight (kg/100 m)
    330.0
  • Diameter (mm) 32
    Minimum breaking force (kN) 1770 N/mm2
    598.0
    Minimum breaking force (kN) 1960 N/mm2
    662.0
    Weight (kg/100 m)
    376.0
  • Diameter (mm) 36
    Minimum breaking force (kN) 1770 N/mm2
    757.0
    Minimum breaking force (kN) 1960 N/mm2
    838.0
    Weight (kg/100 m)
    476.0
  • Diameter (mm) 38
    Minimum breaking force (kN) 1770 N/mm2
    843.0
    Minimum breaking force (kN) 1960 N/mm2
    934.0
    Weight (kg/100 m)
    530.0
  • Diameter (mm) 40
    Minimum breaking force (kN) 1770 N/mm2
    935.0
    Minimum breaking force (kN) 1960 N/mm2
    1040.0
    Weight (kg/100 m)
    587.0
  • Diameter (mm) 44
    Minimum breaking force (kN) 1770 N/mm2
    1130.0
    Minimum breaking force (kN) 1960 N/mm2
    1250.0
    Weight (kg/100 m)
    711.0
  • Diameter (mm) 48
    Minimum breaking force (kN) 1770 N/mm2
    1350.0
    Minimum breaking force (kN) 1960 N/mm2
    1490.0
    Weight (kg/100 m)
    846.0
  • Diameter (mm) 52
    Minimum breaking force (kN) 1770 N/mm2
    1580.0
    Minimum breaking force (kN) 1960 N/mm2
    1750.0
    Weight (kg/100 m)
    992.0
  • Diameter (mm) 56
    Minimum breaking force (kN) 1770 N/mm2
    1830.0
    Minimum breaking force (kN) 1960 N/mm2
    2030.0
    Weight (kg/100 m)
    1150.0
  • Diameter (mm) 60
    Minimum breaking force (kN) 1770 N/mm2
    2100.0
    Minimum breaking force (kN) 1960 N/mm2
    2330.0
    Weight (kg/100 m)
    1320.0

All sizes in the units given in the column header.

Description

About this item

Finish: self-coloured, electro-galvanised or hot-dip galvanised

  • EN 12385-4
  • DIN 3064
  • Wire tensile strength: 1770 N/mm² or 1960 N/mm²
Documentation

Data sheet

  • Steel wire rope 6x36WS with fibre core (FC)PDF, Serbian · 1 page · 209 KB Open Download PDF ↓