SR EN
Account Inquiry
Swivel lifting point G100 RLPSwivel lifting point G100 RLP

Group 02 · 65 items

Grade 80 and Grade 100 fittings

View the group →
Polyester ratchet lashing strap EN 12195-2 ERGO RATCHET RX-liftPolyester ratchet lashing strap EN 12195-2 ERGO RATCHET RX-lift

Group 04 · 16 items

Polyester slings

View the group →
Electric winch type DWElectric winch type DW

Group 06 · 38 items

Electric hoists, winches and pallet trucks

View the group →

Home/Products/Steel wire ropes and chains/General-purpose steel wire ropes/Steel wire rope 6×19 with fibre core (FC)

Steel wire rope 6×19 with fibre core (FC)

EN 12385-4 · DIN 3060 · Finish: electro-galvanised or hot-dip galvanised · Wire tensile strength: 1770 N/mm² or 1960 N/mm²

Choose the variant in the table — every row has “Add to inquiry”.

Overview

At a glance

Tags
  • Steel wire ropes
Table

Sizes and WLL

22 variants from the manufacturer’s table. Add a row to your inquiry — our sales team sends price and availability.

Steel wire rope 6×19 with fibre core (FC) — variant table
Diameter (mm)Minimum breaking force (kN) 1770 N/mm2Minimum breaking force (kN) 1960 N/mm2Weight (kg/100 m)Add to inquiry
34.895.423.11
48.699.635.54
513.6015.08.65
619.6021.712.50
726.629.5017.0
834.838.522.1
944.048.7028.0
1054.360.2034.60
1165.872.841.9
1278.386.7049.80
1391.8101.7058.50
14107.0118.067.80
16139.0154.088.60
18176.0195.0112.0
20217.0241.0138.00
22263.0291.0168.0
24313.0347.0199.0
26367.0407.0234.0
28426.0472.0271.0
32556.0616.0354.0
36704.0780.0448.0
40869.0963.0554.0
  • Diameter (mm) 3
    Minimum breaking force (kN) 1770 N/mm2
    4.89
    Minimum breaking force (kN) 1960 N/mm2
    5.42
    Weight (kg/100 m)
    3.11
  • Diameter (mm) 4
    Minimum breaking force (kN) 1770 N/mm2
    8.69
    Minimum breaking force (kN) 1960 N/mm2
    9.63
    Weight (kg/100 m)
    5.54
  • Diameter (mm) 5
    Minimum breaking force (kN) 1770 N/mm2
    13.60
    Minimum breaking force (kN) 1960 N/mm2
    15.0
    Weight (kg/100 m)
    8.65
  • Diameter (mm) 6
    Minimum breaking force (kN) 1770 N/mm2
    19.60
    Minimum breaking force (kN) 1960 N/mm2
    21.7
    Weight (kg/100 m)
    12.50
  • Diameter (mm) 7
    Minimum breaking force (kN) 1770 N/mm2
    26.6
    Minimum breaking force (kN) 1960 N/mm2
    29.50
    Weight (kg/100 m)
    17.0
  • Diameter (mm) 8
    Minimum breaking force (kN) 1770 N/mm2
    34.8
    Minimum breaking force (kN) 1960 N/mm2
    38.5
    Weight (kg/100 m)
    22.1
  • Diameter (mm) 9
    Minimum breaking force (kN) 1770 N/mm2
    44.0
    Minimum breaking force (kN) 1960 N/mm2
    48.70
    Weight (kg/100 m)
    28.0
  • Diameter (mm) 10
    Minimum breaking force (kN) 1770 N/mm2
    54.3
    Minimum breaking force (kN) 1960 N/mm2
    60.20
    Weight (kg/100 m)
    34.60
  • Diameter (mm) 11
    Minimum breaking force (kN) 1770 N/mm2
    65.8
    Minimum breaking force (kN) 1960 N/mm2
    72.8
    Weight (kg/100 m)
    41.9
  • Diameter (mm) 12
    Minimum breaking force (kN) 1770 N/mm2
    78.3
    Minimum breaking force (kN) 1960 N/mm2
    86.70
    Weight (kg/100 m)
    49.80
  • Diameter (mm) 13
    Minimum breaking force (kN) 1770 N/mm2
    91.8
    Minimum breaking force (kN) 1960 N/mm2
    101.70
    Weight (kg/100 m)
    58.50
  • Diameter (mm) 14
    Minimum breaking force (kN) 1770 N/mm2
    107.0
    Minimum breaking force (kN) 1960 N/mm2
    118.0
    Weight (kg/100 m)
    67.80
  • Diameter (mm) 16
    Minimum breaking force (kN) 1770 N/mm2
    139.0
    Minimum breaking force (kN) 1960 N/mm2
    154.0
    Weight (kg/100 m)
    88.60
  • Diameter (mm) 18
    Minimum breaking force (kN) 1770 N/mm2
    176.0
    Minimum breaking force (kN) 1960 N/mm2
    195.0
    Weight (kg/100 m)
    112.0
  • Diameter (mm) 20
    Minimum breaking force (kN) 1770 N/mm2
    217.0
    Minimum breaking force (kN) 1960 N/mm2
    241.0
    Weight (kg/100 m)
    138.00
  • Diameter (mm) 22
    Minimum breaking force (kN) 1770 N/mm2
    263.0
    Minimum breaking force (kN) 1960 N/mm2
    291.0
    Weight (kg/100 m)
    168.0
  • Diameter (mm) 24
    Minimum breaking force (kN) 1770 N/mm2
    313.0
    Minimum breaking force (kN) 1960 N/mm2
    347.0
    Weight (kg/100 m)
    199.0
  • Diameter (mm) 26
    Minimum breaking force (kN) 1770 N/mm2
    367.0
    Minimum breaking force (kN) 1960 N/mm2
    407.0
    Weight (kg/100 m)
    234.0
  • Diameter (mm) 28
    Minimum breaking force (kN) 1770 N/mm2
    426.0
    Minimum breaking force (kN) 1960 N/mm2
    472.0
    Weight (kg/100 m)
    271.0
  • Diameter (mm) 32
    Minimum breaking force (kN) 1770 N/mm2
    556.0
    Minimum breaking force (kN) 1960 N/mm2
    616.0
    Weight (kg/100 m)
    354.0
  • Diameter (mm) 36
    Minimum breaking force (kN) 1770 N/mm2
    704.0
    Minimum breaking force (kN) 1960 N/mm2
    780.0
    Weight (kg/100 m)
    448.0
  • Diameter (mm) 40
    Minimum breaking force (kN) 1770 N/mm2
    869.0
    Minimum breaking force (kN) 1960 N/mm2
    963.0
    Weight (kg/100 m)
    554.0

All sizes in the units given in the column header.

Description

About this item

Steel wire rope 6×19 with fibre core (FC) — general-purpose wire rope.

  • EN 12385-4
  • DIN 3060
  • Finish: electro-galvanised or hot-dip galvanised
  • Wire tensile strength: 1770 N/mm² or 1960 N/mm²
Documentation

Data sheet

  • Steel wire rope 6×19 with fibre core (FC)PDF, Serbian · 1 page · 181 KB Open Download PDF ↓