
Home/Products/Steel wire ropes and chains/General-purpose steel wire ropes/Steel wire rope 6×19 with fibre core (FC)
Steel wire rope 6×19 with fibre core (FC)
EN 12385-4 · DIN 3060 · Finish: electro-galvanised or hot-dip galvanised · Wire tensile strength: 1770 N/mm² or 1960 N/mm²
- Steel wire ropes and chains
- 22 sizes
Choose the variant in the table — every row has “Add to inquiry”.
Overview
At a glance
- Diameter3–40 mm
- StandardsEN 12385-4, DIN 3060
- DocumentationData sheet (PDF, Serbian)
- Variants22
- SubcategoryGeneral-purpose steel wire ropes
Tags
Table
Sizes and WLL
22 variants from the manufacturer’s table. Add a row to your inquiry — our sales team sends price and availability.
| Diameter (mm) | Minimum breaking force (kN) 1770 N/mm2 | Minimum breaking force (kN) 1960 N/mm2 | Weight (kg/100 m) | Add to inquiry |
|---|---|---|---|---|
| 3 | 4.89 | 5.42 | 3.11 | |
| 4 | 8.69 | 9.63 | 5.54 | |
| 5 | 13.60 | 15.0 | 8.65 | |
| 6 | 19.60 | 21.7 | 12.50 | |
| 7 | 26.6 | 29.50 | 17.0 | |
| 8 | 34.8 | 38.5 | 22.1 | |
| 9 | 44.0 | 48.70 | 28.0 | |
| 10 | 54.3 | 60.20 | 34.60 | |
| 11 | 65.8 | 72.8 | 41.9 | |
| 12 | 78.3 | 86.70 | 49.80 | |
| 13 | 91.8 | 101.70 | 58.50 | |
| 14 | 107.0 | 118.0 | 67.80 | |
| 16 | 139.0 | 154.0 | 88.60 | |
| 18 | 176.0 | 195.0 | 112.0 | |
| 20 | 217.0 | 241.0 | 138.00 | |
| 22 | 263.0 | 291.0 | 168.0 | |
| 24 | 313.0 | 347.0 | 199.0 | |
| 26 | 367.0 | 407.0 | 234.0 | |
| 28 | 426.0 | 472.0 | 271.0 | |
| 32 | 556.0 | 616.0 | 354.0 | |
| 36 | 704.0 | 780.0 | 448.0 | |
| 40 | 869.0 | 963.0 | 554.0 |
- Diameter (mm) 3
- Minimum breaking force (kN) 1770 N/mm2
- 4.89
- Minimum breaking force (kN) 1960 N/mm2
- 5.42
- Weight (kg/100 m)
- 3.11
- Diameter (mm) 4
- Minimum breaking force (kN) 1770 N/mm2
- 8.69
- Minimum breaking force (kN) 1960 N/mm2
- 9.63
- Weight (kg/100 m)
- 5.54
- Diameter (mm) 5
- Minimum breaking force (kN) 1770 N/mm2
- 13.60
- Minimum breaking force (kN) 1960 N/mm2
- 15.0
- Weight (kg/100 m)
- 8.65
- Diameter (mm) 6
- Minimum breaking force (kN) 1770 N/mm2
- 19.60
- Minimum breaking force (kN) 1960 N/mm2
- 21.7
- Weight (kg/100 m)
- 12.50
- Diameter (mm) 7
- Minimum breaking force (kN) 1770 N/mm2
- 26.6
- Minimum breaking force (kN) 1960 N/mm2
- 29.50
- Weight (kg/100 m)
- 17.0
- Diameter (mm) 8
- Minimum breaking force (kN) 1770 N/mm2
- 34.8
- Minimum breaking force (kN) 1960 N/mm2
- 38.5
- Weight (kg/100 m)
- 22.1
- Diameter (mm) 9
- Minimum breaking force (kN) 1770 N/mm2
- 44.0
- Minimum breaking force (kN) 1960 N/mm2
- 48.70
- Weight (kg/100 m)
- 28.0
- Diameter (mm) 10
- Minimum breaking force (kN) 1770 N/mm2
- 54.3
- Minimum breaking force (kN) 1960 N/mm2
- 60.20
- Weight (kg/100 m)
- 34.60
- Diameter (mm) 11
- Minimum breaking force (kN) 1770 N/mm2
- 65.8
- Minimum breaking force (kN) 1960 N/mm2
- 72.8
- Weight (kg/100 m)
- 41.9
- Diameter (mm) 12
- Minimum breaking force (kN) 1770 N/mm2
- 78.3
- Minimum breaking force (kN) 1960 N/mm2
- 86.70
- Weight (kg/100 m)
- 49.80
- Diameter (mm) 13
- Minimum breaking force (kN) 1770 N/mm2
- 91.8
- Minimum breaking force (kN) 1960 N/mm2
- 101.70
- Weight (kg/100 m)
- 58.50
- Diameter (mm) 14
- Minimum breaking force (kN) 1770 N/mm2
- 107.0
- Minimum breaking force (kN) 1960 N/mm2
- 118.0
- Weight (kg/100 m)
- 67.80
- Diameter (mm) 16
- Minimum breaking force (kN) 1770 N/mm2
- 139.0
- Minimum breaking force (kN) 1960 N/mm2
- 154.0
- Weight (kg/100 m)
- 88.60
- Diameter (mm) 18
- Minimum breaking force (kN) 1770 N/mm2
- 176.0
- Minimum breaking force (kN) 1960 N/mm2
- 195.0
- Weight (kg/100 m)
- 112.0
- Diameter (mm) 20
- Minimum breaking force (kN) 1770 N/mm2
- 217.0
- Minimum breaking force (kN) 1960 N/mm2
- 241.0
- Weight (kg/100 m)
- 138.00
- Diameter (mm) 22
- Minimum breaking force (kN) 1770 N/mm2
- 263.0
- Minimum breaking force (kN) 1960 N/mm2
- 291.0
- Weight (kg/100 m)
- 168.0
- Diameter (mm) 24
- Minimum breaking force (kN) 1770 N/mm2
- 313.0
- Minimum breaking force (kN) 1960 N/mm2
- 347.0
- Weight (kg/100 m)
- 199.0
- Diameter (mm) 26
- Minimum breaking force (kN) 1770 N/mm2
- 367.0
- Minimum breaking force (kN) 1960 N/mm2
- 407.0
- Weight (kg/100 m)
- 234.0
- Diameter (mm) 28
- Minimum breaking force (kN) 1770 N/mm2
- 426.0
- Minimum breaking force (kN) 1960 N/mm2
- 472.0
- Weight (kg/100 m)
- 271.0
- Diameter (mm) 32
- Minimum breaking force (kN) 1770 N/mm2
- 556.0
- Minimum breaking force (kN) 1960 N/mm2
- 616.0
- Weight (kg/100 m)
- 354.0
- Diameter (mm) 36
- Minimum breaking force (kN) 1770 N/mm2
- 704.0
- Minimum breaking force (kN) 1960 N/mm2
- 780.0
- Weight (kg/100 m)
- 448.0
- Diameter (mm) 40
- Minimum breaking force (kN) 1770 N/mm2
- 869.0
- Minimum breaking force (kN) 1960 N/mm2
- 963.0
- Weight (kg/100 m)
- 554.0
All sizes in the units given in the column header.
Description
About this item
Steel wire rope 6×19 with fibre core (FC) — general-purpose wire rope.
- EN 12385-4
- DIN 3060
- Finish: electro-galvanised or hot-dip galvanised
- Wire tensile strength: 1770 N/mm² or 1960 N/mm²
Documentation
Data sheet
- Steel wire rope 6×19 with fibre core (FC)PDF, Serbian · 1 page · 181 KB Open Download PDF ↓
Related products
From the same subcategory




Steel wire rope 6×19 with fibre core (FC)
Add to inquiry ↓






