SR EN
Account Inquiry
Swivel lifting point G100 RLPSwivel lifting point G100 RLP

Group 02 · 65 items

Grade 80 and Grade 100 fittings

View the group →
Polyester ratchet lashing strap EN 12195-2 ERGO RATCHET RX-liftPolyester ratchet lashing strap EN 12195-2 ERGO RATCHET RX-lift

Group 04 · 16 items

Polyester slings

View the group →
Electric winch type DWElectric winch type DW

Group 06 · 38 items

Electric hoists, winches and pallet trucks

View the group →

Home/Products/Steel wire ropes and chains/General-purpose steel wire ropes/Steel wire rope 6x36WS with steel core (IWRC)

Steel wire rope 6x36WS with steel core (IWRC)

EN 12385-4 · DIN 3064 · Finish: self-coloured, electro-galvanised or hot-dip galvanised · Wire tensile strength: 1960 N/mm² or 2160 N/mm²

Choose the variant in the table — every row has “Add to inquiry”.

Overview

At a glance

Tags
  • Steel wire ropes
Table

Sizes and WLL

42 variants from the manufacturer’s table. Add a row to your inquiry — our sales team sends price and availability.

Steel wire rope 6x36WS with steel core (IWRC) — variant table
Diameter (mm)Minimum breaking force (kN) 1960 N/mm2Minimum breaking force (kN) 2160 N/mm2Weight (kg/100 m)Add to inquiry
6252815
8454926
9576233
10707741
11849349
1210011159
1311813069
1413715180
1515717392
16179197105
17202222118
18226249133
19252278148
20279308164
21308339180
22338372198
23369407216
24402443236
25436481256
26472520276
27509561298
28547603321
29587647344
30628692368
32715787419
34807889473
36904997530
3810081110591
4011161230654
4212311356721
4413511489792
4614761627865
4816081772942
50174419221023
52188720791106
54203522421193
56218824111283
58234725871376
60251227681472
62268229561572
66303933501782
70341937682004
  • Diameter (mm) 6
    Minimum breaking force (kN) 1960 N/mm2
    25
    Minimum breaking force (kN) 2160 N/mm2
    28
    Weight (kg/100 m)
    15
  • Diameter (mm) 8
    Minimum breaking force (kN) 1960 N/mm2
    45
    Minimum breaking force (kN) 2160 N/mm2
    49
    Weight (kg/100 m)
    26
  • Diameter (mm) 9
    Minimum breaking force (kN) 1960 N/mm2
    57
    Minimum breaking force (kN) 2160 N/mm2
    62
    Weight (kg/100 m)
    33
  • Diameter (mm) 10
    Minimum breaking force (kN) 1960 N/mm2
    70
    Minimum breaking force (kN) 2160 N/mm2
    77
    Weight (kg/100 m)
    41
  • Diameter (mm) 11
    Minimum breaking force (kN) 1960 N/mm2
    84
    Minimum breaking force (kN) 2160 N/mm2
    93
    Weight (kg/100 m)
    49
  • Diameter (mm) 12
    Minimum breaking force (kN) 1960 N/mm2
    100
    Minimum breaking force (kN) 2160 N/mm2
    111
    Weight (kg/100 m)
    59
  • Diameter (mm) 13
    Minimum breaking force (kN) 1960 N/mm2
    118
    Minimum breaking force (kN) 2160 N/mm2
    130
    Weight (kg/100 m)
    69
  • Diameter (mm) 14
    Minimum breaking force (kN) 1960 N/mm2
    137
    Minimum breaking force (kN) 2160 N/mm2
    151
    Weight (kg/100 m)
    80
  • Diameter (mm) 15
    Minimum breaking force (kN) 1960 N/mm2
    157
    Minimum breaking force (kN) 2160 N/mm2
    173
    Weight (kg/100 m)
    92
  • Diameter (mm) 16
    Minimum breaking force (kN) 1960 N/mm2
    179
    Minimum breaking force (kN) 2160 N/mm2
    197
    Weight (kg/100 m)
    105
  • Diameter (mm) 17
    Minimum breaking force (kN) 1960 N/mm2
    202
    Minimum breaking force (kN) 2160 N/mm2
    222
    Weight (kg/100 m)
    118
  • Diameter (mm) 18
    Minimum breaking force (kN) 1960 N/mm2
    226
    Minimum breaking force (kN) 2160 N/mm2
    249
    Weight (kg/100 m)
    133
  • Diameter (mm) 19
    Minimum breaking force (kN) 1960 N/mm2
    252
    Minimum breaking force (kN) 2160 N/mm2
    278
    Weight (kg/100 m)
    148
  • Diameter (mm) 20
    Minimum breaking force (kN) 1960 N/mm2
    279
    Minimum breaking force (kN) 2160 N/mm2
    308
    Weight (kg/100 m)
    164
  • Diameter (mm) 21
    Minimum breaking force (kN) 1960 N/mm2
    308
    Minimum breaking force (kN) 2160 N/mm2
    339
    Weight (kg/100 m)
    180
  • Diameter (mm) 22
    Minimum breaking force (kN) 1960 N/mm2
    338
    Minimum breaking force (kN) 2160 N/mm2
    372
    Weight (kg/100 m)
    198
  • Diameter (mm) 23
    Minimum breaking force (kN) 1960 N/mm2
    369
    Minimum breaking force (kN) 2160 N/mm2
    407
    Weight (kg/100 m)
    216
  • Diameter (mm) 24
    Minimum breaking force (kN) 1960 N/mm2
    402
    Minimum breaking force (kN) 2160 N/mm2
    443
    Weight (kg/100 m)
    236
  • Diameter (mm) 25
    Minimum breaking force (kN) 1960 N/mm2
    436
    Minimum breaking force (kN) 2160 N/mm2
    481
    Weight (kg/100 m)
    256
  • Diameter (mm) 26
    Minimum breaking force (kN) 1960 N/mm2
    472
    Minimum breaking force (kN) 2160 N/mm2
    520
    Weight (kg/100 m)
    276
  • Diameter (mm) 27
    Minimum breaking force (kN) 1960 N/mm2
    509
    Minimum breaking force (kN) 2160 N/mm2
    561
    Weight (kg/100 m)
    298
  • Diameter (mm) 28
    Minimum breaking force (kN) 1960 N/mm2
    547
    Minimum breaking force (kN) 2160 N/mm2
    603
    Weight (kg/100 m)
    321
  • Diameter (mm) 29
    Minimum breaking force (kN) 1960 N/mm2
    587
    Minimum breaking force (kN) 2160 N/mm2
    647
    Weight (kg/100 m)
    344
  • Diameter (mm) 30
    Minimum breaking force (kN) 1960 N/mm2
    628
    Minimum breaking force (kN) 2160 N/mm2
    692
    Weight (kg/100 m)
    368
  • Diameter (mm) 32
    Minimum breaking force (kN) 1960 N/mm2
    715
    Minimum breaking force (kN) 2160 N/mm2
    787
    Weight (kg/100 m)
    419
  • Diameter (mm) 34
    Minimum breaking force (kN) 1960 N/mm2
    807
    Minimum breaking force (kN) 2160 N/mm2
    889
    Weight (kg/100 m)
    473
  • Diameter (mm) 36
    Minimum breaking force (kN) 1960 N/mm2
    904
    Minimum breaking force (kN) 2160 N/mm2
    997
    Weight (kg/100 m)
    530
  • Diameter (mm) 38
    Minimum breaking force (kN) 1960 N/mm2
    1008
    Minimum breaking force (kN) 2160 N/mm2
    1110
    Weight (kg/100 m)
    591
  • Diameter (mm) 40
    Minimum breaking force (kN) 1960 N/mm2
    1116
    Minimum breaking force (kN) 2160 N/mm2
    1230
    Weight (kg/100 m)
    654
  • Diameter (mm) 42
    Minimum breaking force (kN) 1960 N/mm2
    1231
    Minimum breaking force (kN) 2160 N/mm2
    1356
    Weight (kg/100 m)
    721
  • Diameter (mm) 44
    Minimum breaking force (kN) 1960 N/mm2
    1351
    Minimum breaking force (kN) 2160 N/mm2
    1489
    Weight (kg/100 m)
    792
  • Diameter (mm) 46
    Minimum breaking force (kN) 1960 N/mm2
    1476
    Minimum breaking force (kN) 2160 N/mm2
    1627
    Weight (kg/100 m)
    865
  • Diameter (mm) 48
    Minimum breaking force (kN) 1960 N/mm2
    1608
    Minimum breaking force (kN) 2160 N/mm2
    1772
    Weight (kg/100 m)
    942
  • Diameter (mm) 50
    Minimum breaking force (kN) 1960 N/mm2
    1744
    Minimum breaking force (kN) 2160 N/mm2
    1922
    Weight (kg/100 m)
    1023
  • Diameter (mm) 52
    Minimum breaking force (kN) 1960 N/mm2
    1887
    Minimum breaking force (kN) 2160 N/mm2
    2079
    Weight (kg/100 m)
    1106
  • Diameter (mm) 54
    Minimum breaking force (kN) 1960 N/mm2
    2035
    Minimum breaking force (kN) 2160 N/mm2
    2242
    Weight (kg/100 m)
    1193
  • Diameter (mm) 56
    Minimum breaking force (kN) 1960 N/mm2
    2188
    Minimum breaking force (kN) 2160 N/mm2
    2411
    Weight (kg/100 m)
    1283
  • Diameter (mm) 58
    Minimum breaking force (kN) 1960 N/mm2
    2347
    Minimum breaking force (kN) 2160 N/mm2
    2587
    Weight (kg/100 m)
    1376
  • Diameter (mm) 60
    Minimum breaking force (kN) 1960 N/mm2
    2512
    Minimum breaking force (kN) 2160 N/mm2
    2768
    Weight (kg/100 m)
    1472
  • Diameter (mm) 62
    Minimum breaking force (kN) 1960 N/mm2
    2682
    Minimum breaking force (kN) 2160 N/mm2
    2956
    Weight (kg/100 m)
    1572
  • Diameter (mm) 66
    Minimum breaking force (kN) 1960 N/mm2
    3039
    Minimum breaking force (kN) 2160 N/mm2
    3350
    Weight (kg/100 m)
    1782
  • Diameter (mm) 70
    Minimum breaking force (kN) 1960 N/mm2
    3419
    Minimum breaking force (kN) 2160 N/mm2
    3768
    Weight (kg/100 m)
    2004

All sizes in the units given in the column header.

Description

About this item

Finish: self-coloured, electro-galvanised or hot-dip galvanised

  • EN 12385-4
  • DIN 3064
  • Wire tensile strength: 1960 N/mm² or 2160 N/mm²
Documentation

Data sheet

  • Steel wire rope 6x36WS with steel core (IWRC)PDF, Serbian · 1 page · 213 KB Open Download PDF ↓